RIDE GEAR GUIDE / RV WATER & MAINTENANCE

Best RV Tankless Water Heaters

Compare RV-rated propane tankless heaters by BTU input, flow limitations, cutout size, venting and real retrofit requirements.

Compare Current Options
BUYER’S GUIDEPROPANE + 12V DCRETROFIT FITMENT

Replacing a six-gallon tank does not simply mean buying a unit with a larger advertised GPM number. A tankless heater has to fit an RV wall opening, vent combustion gases safely and raise incoming water to shower temperature while water is flowing. This comparison focuses on four distinct RV propane models, separating verified specifications from assumptions about real-world performance.

As an Amazon Associate, we earn from qualifying purchases.

01 RV tankless heater shortlist

These four RV-rated choices cover two Suburban heat-input classes and two Fogatti output configurations.

Higher-input RV retrofitSuburban ST-60

Suburban publishes a 60,000 BTU/h input rating, a 0.7 GPM minimum activation flow, a 12V electrical requirement and a 131°F maximum outlet setting for its ST-60.

Heat input60,000 BTU/h inputKey spec12V DC · 0.7 GPM minimum activation
Lower-input Suburban alternativeSuburban ST-42

The ST-42 shares the ST series installation concept and listed minimum activation flow, but its maximum heat input is 42,000 BTU/h rather than 60,000.

Heat input42,000 BTU/h inputKey spec12V DC · 0.7 GPM minimum activation
Mid-size family shower optionFogatti InstaShower 8 Plus

Fogatti lists a 55,000 BTU/h heater with up to 2.9 GPM, selectable 95–123°F outlet temperature and a minimum 13-by-13-inch cutout.

Heat input55,000 BTU/h inputKey specUp to 2.9 GPM claimed · 12V DC
Higher-flow model with mixing tankFogatti InstaShower 9 Pro

Fogatti differentiates its 9 Pro with a 66,000 BTU/h input class, up to 3.6 GPM published flow and an integrated mixing tank.

Heat input66,000 BTU/h inputKey specUp to 3.6 GPM claimed · mixing tank

02 Compare heat input and fitment

BTU/h measures heat input; advertised maximum GPM may be measured under conditions unlike a cold-weather RV shower.

Exact modelHeat inputPublished distinctionBest-fit scenario
Suburban ST-6060,000 BTU/h input12V DC · 0.7 GPM minimum activationHigher-input RV retrofit
Suburban ST-4242,000 BTU/h input12V DC · 0.7 GPM minimum activationLower-input Suburban alternative
Fogatti InstaShower 8 Plus55,000 BTU/h inputUp to 2.9 GPM claimed · 12V DCMid-size family shower option
Fogatti InstaShower 9 Pro66,000 BTU/h inputUp to 3.6 GPM claimed · mixing tankHigher-flow model with mixing tank

03 Four RV-rated heater options

Manufacturer specifications are cited for each model; this guide does not claim hands-on installation, performance testing or a measured ranking.

01 / Higher-input RV retrofit

Suburban ST-60

60,000 BTU/h input12V DC · 0.7 GPM minimum activation

Suburban publishes a 60,000 BTU/h input rating, a 0.7 GPM minimum activation flow, a 12V electrical requirement and a 131°F maximum outlet setting for its ST-60.

Best fit: RVs whose hot-water demand and certified installation opening justify the higher heat-input class.

Why consider it

RVs whose hot-water demand and certified installation opening justify the higher heat-input class.

Installation caveat

Confirm the full vent, access-door, LP gas, wiring and water connection arrangement with an authorized installer; nominal input is not a promised GPM at a given temperature rise.

Manufacturer source: Product specification or official series comparison. Figures are manufacturer-published, not independent test results.

Check Price
02 / Lower-input Suburban alternative

Suburban ST-42

42,000 BTU/h input12V DC · 0.7 GPM minimum activation

The ST-42 shares the ST series installation concept and listed minimum activation flow, but its maximum heat input is 42,000 BTU/h rather than 60,000.

Best fit: Smaller RVs with compatible openings and lower expected simultaneous hot-water demand.

Why consider it

Smaller RVs with compatible openings and lower expected simultaneous hot-water demand.

Installation caveat

A lower input rating can limit available hot-water flow in cold inlet-water conditions; do not assume the same shower performance as the ST-60.

Manufacturer source: Product specification or official series comparison. Figures are manufacturer-published, not independent test results.

Check Price
03 / Mid-size family shower option

Fogatti InstaShower 8 Plus

55,000 BTU/h inputUp to 2.9 GPM claimed · 12V DC

Fogatti lists a 55,000 BTU/h heater with up to 2.9 GPM, selectable 95–123°F outlet temperature and a minimum 13-by-13-inch cutout.

Best fit: Mid-size travel trailers or Class C RVs seeking a manufacturer-listed flow benchmark and compatible exterior door kit.

Why consider it

Mid-size travel trailers or Class C RVs seeking a manufacturer-listed flow benchmark and compatible exterior door kit.

Installation caveat

The up-to GPM figure depends on inlet temperature and required temperature rise. Select a door size that covers the actual exterior opening.

Manufacturer source: Product specification or official series comparison. Figures are manufacturer-published, not independent test results.

Check Price
04 / Higher-flow model with mixing tank

Fogatti InstaShower 9 Pro

66,000 BTU/h inputUp to 3.6 GPM claimed · mixing tank

Fogatti differentiates its 9 Pro with a 66,000 BTU/h input class, up to 3.6 GPM published flow and an integrated mixing tank.

Best fit: Larger RVs that can support its installation requirements and need more hot-water output margin.

Why consider it

Larger RVs that can support its installation requirements and need more hot-water output margin.

Installation caveat

Do not read the maximum GPM as guaranteed in winter; verify LP capacity, minimum flow, access door and exterior clearances.

Manufacturer source: Product specification or official series comparison. Figures are manufacturer-published, not independent test results.

Check Price

04 Seven critical retrofit checks

LP gas and combustion venting create serious safety hazards. Installation and servicing should be performed by a qualified RV technician.

  1. Confirm RV-specific certification: Choose an RV-rated, externally vented appliance; a household or portable outdoor shower heater is not an interchangeable RV installation.
  2. Measure the existing rough opening and exterior door: Record the cutout, wall depth, framing, door coverage and vent path. A nominal 13-by-13-inch cutout does not guarantee a drop-in retrofit.
  3. Calculate hot-water output from inlet temperature: BTU input and maximum GPM cannot be compared without the required temperature rise. Cold campground water can sharply reduce useful shower flow.
  4. Check propane supply and combustion requirements: A qualified RV technician should verify LP regulator capacity, gas piping, combustion air, exhaust clearances and appliance-specific venting.
  5. Verify 12V DC power and controls: Confirm the model-specific fuse, wiring, controller routing and supply stability. These propane heaters still need DC power for electronics and ignition.
  6. Check minimum activation flow and water pressure: Low-flow fixtures, pump cycling or restricted plumbing can prevent reliable ignition. Match operating requirements to the RV pump and city-water setup.
  7. Plan freeze protection and professional commissioning: Powered freeze protection may stop working without electricity or propane. Follow the manufacturer winterization procedure and have a qualified installer leak-test and commission the unit.

05 Choose for your temperature rise

Cold-water camping: evaluate required temperature rise before comparing maximum GPM claims. A heater must add more energy per gallon when inlet water is colder, reducing achievable flow at a given output temperature.

Smaller RV with modest demand: Suburban ST-42 offers a 42,000 BTU/h class; verify that its heat input and activation flow meet your actual fixtures.

Higher heat input: Suburban ST-60 publishes 60,000 BTU/h, with a 0.7 GPM minimum activation flow for the ST series. The Fogatti 9 Pro is rated at 66,000 BTU/h with a mixing tank, but retrofit fit still comes first.

Water delivery problems: If hot-water flow is inconsistent because of the freshwater pump, start with RV water pump selection. If pressure varies only on campground hookups, compare RV pressure regulators.

06 Frequently asked questions

Are RV tankless water heaters truly unlimited?

They heat water continuously while adequate propane, 12V power and water flow are available. Their output is still limited by heat input and the inlet-water temperature.

How many GPM do I need for an RV shower?

Start with the actual showerhead flow and cold-water temperature. Published maximum GPM is not necessarily the hot-water flow achievable at the temperature rise you need.

Can I install a residential tankless heater in an RV?

Do not substitute a residential or outdoor portable unit for an RV-certified heater. Venting, vibration, combustion and installation standards differ.

Will a tankless heater work with my 12V RV water pump?

It may, if the pump can maintain the heater’s required operating pressure and minimum activation flow. Verify the exact specifications for both devices.

Does tankless save propane compared with a tank heater?

It avoids continuously maintaining a storage tank at temperature, but actual propane use depends on hot-water volume, temperature rise, burner efficiency and habits.

Do tankless RV heaters need winterizing?

Yes. Some models provide powered freeze protection, but protection has operating conditions and does not replace the manufacturer’s winterization instructions.

07 Prioritize certified RV fitment

The strongest choice is not automatically the heater with the largest input or maximum-flow claim. Verify the existing wall opening, approved exhaust path, LP and 12V requirements, activation flow and realistic temperature rise before committing. Have a qualified RV technician handle installation and commissioning.

Scroll to Top